您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览0

The aim of this study was to determine the size distribution of bacteria and fungi occurring in the air of human dwellings. The concentration and size distribution of particulate aerosol, Gram-positive mesophilic bacteria, Gram-negative mesophilic bacteria and fungi were examined in 60 flats situated in the Upper Silesia conurbation, southern Poland. The investigated flats comprised three quantitatively equal (20 flats each) groups: flats without additional emission sources of particulate aerosol and microorganisms (Group I), flats with persons who smoke at least one packet of cigarettes per day (Group II), and flats located near steelworks (Group III). The concentrations of four fractions of particulate aerosol were measured by Harvard impactors (PM 2.5 and PM 10) as well as by cyclone HD and 37 mm filter disc holder (PM 5 and TSP). The concentrations of bacteria and fungi were measured by a particle-sizing six-stage Graseby-Andersen impactor. It was found that the concentrations of particulate aerosol in examined flats were below 0.6 mg/m.(3) and the concentrations of microorganisms were below the level of 10(4) cfu/m.(3). The dominant bacteria present in the air of examined dwellings (Micrococcus/Kocuria spp., Staphylococcus spp., Bacillus spp., Pseudomonadaceae, Aeromonas spp., Nocardia spp.) occurred mostly as single particles in the dwellings without additional emission sources, while in the air of dwellings inhabited by tobacco smokers, they often formed aggregates composed of bacterial and dust particles. The fungi dominant in the air of examined dwellings (Penicillium spp., Aspergillus spp., yeasts) occurred mostly as single particles.

作者:R L, Górny;J, Dutkiewicz;E, Krysińska-Traczyk

来源:Annals of agricultural and environmental medicine : AAEM 1999 年 6卷 2期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:0
作者:
R L, Górny;J, Dutkiewicz;E, Krysińska-Traczyk
来源:
Annals of agricultural and environmental medicine : AAEM 1999 年 6卷 2期
The aim of this study was to determine the size distribution of bacteria and fungi occurring in the air of human dwellings. The concentration and size distribution of particulate aerosol, Gram-positive mesophilic bacteria, Gram-negative mesophilic bacteria and fungi were examined in 60 flats situated in the Upper Silesia conurbation, southern Poland. The investigated flats comprised three quantitatively equal (20 flats each) groups: flats without additional emission sources of particulate aerosol and microorganisms (Group I), flats with persons who smoke at least one packet of cigarettes per day (Group II), and flats located near steelworks (Group III). The concentrations of four fractions of particulate aerosol were measured by Harvard impactors (PM 2.5 and PM 10) as well as by cyclone HD and 37 mm filter disc holder (PM 5 and TSP). The concentrations of bacteria and fungi were measured by a particle-sizing six-stage Graseby-Andersen impactor. It was found that the concentrations of particulate aerosol in examined flats were below 0.6 mg/m.(3) and the concentrations of microorganisms were below the level of 10(4) cfu/m.(3). The dominant bacteria present in the air of examined dwellings (Micrococcus/Kocuria spp., Staphylococcus spp., Bacillus spp., Pseudomonadaceae, Aeromonas spp., Nocardia spp.) occurred mostly as single particles in the dwellings without additional emission sources, while in the air of dwellings inhabited by tobacco smokers, they often formed aggregates composed of bacterial and dust particles. The fungi dominant in the air of examined dwellings (Penicillium spp., Aspergillus spp., yeasts) occurred mostly as single particles.