您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览2

Biomechanical models which require information on, e.g., joint torque and muscle force are useful in the estimation of when and how mechanical overload of the musculoskeletal system may lead to disorders. The aim was to study the reliability and validity of magnetic resonance imaging (MRI) to quantify muscle sizes and moment arms by MRI and to test selected anthropometric measures as predictors of muscle sizes and moment arms. A total of 20 healthy Scandinavian women (age 22-58 years) participated in an MRI scanning of their dominant shoulder. With a PC-based program the reliability and the validity of the MRI measurements was estimated to be high, and mean anatomical cross-sectional areas (ACSA) and muscle lengths were measured to be 4.0, 9.8 and 12.1 cm(2) and 12.0, 12.6 and 12.8 cm for m. supraspinatus, m. infraspinatus and m. subscapularis, respectively. Volumes were calculated to be 48.8, 125.1 and 153.6 cm(3). Moment arms were measured with the upper arm in a neutral position and in a functional position of 34 degrees abduction for m. supraspinatus only, and were 2.4 and 2.6 cm. Physiological cross-sectional area (PCSA) and its fiber force component were estimated from dissected fiber length and pennation angle. MRI volume and PCSA were 1.4-1.7 times higher than dissection data, primarily because of age differences. No external anthropometric measures were found to be predictors of volumes or moment arms.

作者:B, Juul-Kristensen;F, Bojsen-Moller;L, Finsen;J, Eriksson;G, Johansson;F, Stahlberg;C, Ekdahl

来源:Cells, tissues, organs 2000 年 167卷 2-3期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:2
作者:
B, Juul-Kristensen;F, Bojsen-Moller;L, Finsen;J, Eriksson;G, Johansson;F, Stahlberg;C, Ekdahl
来源:
Cells, tissues, organs 2000 年 167卷 2-3期
Biomechanical models which require information on, e.g., joint torque and muscle force are useful in the estimation of when and how mechanical overload of the musculoskeletal system may lead to disorders. The aim was to study the reliability and validity of magnetic resonance imaging (MRI) to quantify muscle sizes and moment arms by MRI and to test selected anthropometric measures as predictors of muscle sizes and moment arms. A total of 20 healthy Scandinavian women (age 22-58 years) participated in an MRI scanning of their dominant shoulder. With a PC-based program the reliability and the validity of the MRI measurements was estimated to be high, and mean anatomical cross-sectional areas (ACSA) and muscle lengths were measured to be 4.0, 9.8 and 12.1 cm(2) and 12.0, 12.6 and 12.8 cm for m. supraspinatus, m. infraspinatus and m. subscapularis, respectively. Volumes were calculated to be 48.8, 125.1 and 153.6 cm(3). Moment arms were measured with the upper arm in a neutral position and in a functional position of 34 degrees abduction for m. supraspinatus only, and were 2.4 and 2.6 cm. Physiological cross-sectional area (PCSA) and its fiber force component were estimated from dissected fiber length and pennation angle. MRI volume and PCSA were 1.4-1.7 times higher than dissection data, primarily because of age differences. No external anthropometric measures were found to be predictors of volumes or moment arms.