您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览6

The flow capacity of the right gastroepiploic artery graft has not been clarified.Angiographic and echocardiographic studies were conducted in 30 patients who had undergone coronary artery bypass grafting using both the internal thoracic and right gastroepiploic arteries. The luminal diameter of the arterial grafts was measured from the postoperative angiograms. The adequacy of the myocardial blood supply from the arterial grafts was evaluated by dobutamine stress echocardiography.With echocardiography, 14 patients exhibited an ischemic response in the gastroepiploic artery grafted region, whereas no patients exhibited an ischemic response in the internal thoracic artery grafted area. The luminal diameter of the gastroepiploic artery and a younger age were correlated with the ischemic response observed in the dobutamine stress echocardiography. A luminal diameter of the gastroepiploic artery of greater than 2.6 mm had the highest sensitivity and specificity for a nonischemic change.To generate the maximal flow reserve, the luminal diameter of the gastroepiploic artery when used as a graft should be sufficiently large enough, nearly 3 mm at the anastomosis.

作者:M, Ochi;N, Hatori;M, Fujii;Y, Saji;S, Tanaka;H, Honma

来源:The Annals of thoracic surgery 2001 年 71卷 4期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:6
作者:
M, Ochi;N, Hatori;M, Fujii;Y, Saji;S, Tanaka;H, Honma
来源:
The Annals of thoracic surgery 2001 年 71卷 4期
The flow capacity of the right gastroepiploic artery graft has not been clarified.Angiographic and echocardiographic studies were conducted in 30 patients who had undergone coronary artery bypass grafting using both the internal thoracic and right gastroepiploic arteries. The luminal diameter of the arterial grafts was measured from the postoperative angiograms. The adequacy of the myocardial blood supply from the arterial grafts was evaluated by dobutamine stress echocardiography.With echocardiography, 14 patients exhibited an ischemic response in the gastroepiploic artery grafted region, whereas no patients exhibited an ischemic response in the internal thoracic artery grafted area. The luminal diameter of the gastroepiploic artery and a younger age were correlated with the ischemic response observed in the dobutamine stress echocardiography. A luminal diameter of the gastroepiploic artery of greater than 2.6 mm had the highest sensitivity and specificity for a nonischemic change.To generate the maximal flow reserve, the luminal diameter of the gastroepiploic artery when used as a graft should be sufficiently large enough, nearly 3 mm at the anastomosis.