您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览0

A navigation system should improve the quality of a total knee prosthesis implantation in comparison to that obtained with the classical, surgeon-controlled operative technique. The authors implanted 30 total knee prostheses with an infrared navigation system (Orthopilot, Aesculap, Tuttlingen, Germany). The quality of implantation was studied on postoperative long-leg coronal and lateral X-rays, and compared to a control group of 30 matched-paired total knee prostheses of the same type (Search prosthesis, Aesculap, Tuttlingen, Germany) implanted with a classical, surgeon-controlled technique. An optimal mechanical femorotibial angle (177 to 183 degrees) was obtained in 25 cases in the study group and 21 cases in the control group (p > 0.05). Similar differences were seen for the coronal and sagittal orientations of both tibial and femoral components. Globally, 23 cases in the study group and 8 cases in the control group were implanted in an optimal manner for all studied criteria (p < 0.001). The navigation system used allows a significant improvement in the quality of implantation of a total knee prosthesis in comparison to that obtained with a classical, surgeon-controlled instrumentation, and long-term outcome could consequently be improved.

作者:J Y, Jenny;C, Boeri

来源:Computer aided surgery : official journal of the International Society for Computer Aided Surgery 2001 年 6卷 4期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:0
作者:
J Y, Jenny;C, Boeri
来源:
Computer aided surgery : official journal of the International Society for Computer Aided Surgery 2001 年 6卷 4期
A navigation system should improve the quality of a total knee prosthesis implantation in comparison to that obtained with the classical, surgeon-controlled operative technique. The authors implanted 30 total knee prostheses with an infrared navigation system (Orthopilot, Aesculap, Tuttlingen, Germany). The quality of implantation was studied on postoperative long-leg coronal and lateral X-rays, and compared to a control group of 30 matched-paired total knee prostheses of the same type (Search prosthesis, Aesculap, Tuttlingen, Germany) implanted with a classical, surgeon-controlled technique. An optimal mechanical femorotibial angle (177 to 183 degrees) was obtained in 25 cases in the study group and 21 cases in the control group (p > 0.05). Similar differences were seen for the coronal and sagittal orientations of both tibial and femoral components. Globally, 23 cases in the study group and 8 cases in the control group were implanted in an optimal manner for all studied criteria (p < 0.001). The navigation system used allows a significant improvement in the quality of implantation of a total knee prosthesis in comparison to that obtained with a classical, surgeon-controlled instrumentation, and long-term outcome could consequently be improved.