The purpose of this case study was to improve stability, posture, and speed of gait in an individual with paraplegia through the application of a hybrid system including trunk-hip-knee-ankle-foot orthosis (THKAFO) with lockable joints and multichannel functional electrical stimulation (FES) with implanted electrodes.Two hybrid orthoses were implemented and evaluated on a person with complete absence of motor function and sensation below the T-9 level spinal cord injury. The first hybrid was a modified isocentric reciprocal gait orthosis (IRGO) with the knees controlled by FES, the ankles fixed at neutral, and the hips coupled with a reciprocator. The second hybrid had a THKAFO instrumented with lockable joints using wrap-spring clutches at the hips and knees (THKAFO-LJ) that provided free extension and allowed for flexion only when disengaged by solenoids. A microprocessor-controlled stimulator provided muscle stimulation and activation signals for the solenoids. These two hybrid systems were compared with an FES-only system.The IRGO hybrid system with the hip reciprocator engaged provided a stable gait with erect posture with minimal anterior trunk lean using only quad canes for support. However, the walking speed was slow, due to limited step length imposed by the reciprocator. The walking speed with the THKAFO-LJ hybrid system was significantly faster than that with the IRGO hybrid with the reciprocator engaged, and was comparable with the FES-only gait; however, it resulted in excessive anterior trunk lean. A walker with 2 wheels was required to maintain balance.The results point to the need for a hybrid system that allows for unencumbered hip and knee joint motion for stepping without excessive anterior trunk lean. Such a hybrid system could provide a reasonable speed in gait powered by muscle stimulation, without the usual joint motion constraints imposed by the bracing, while providing stability that is normally seen only with bracing. Further advantages would include reduction in required stimulation during standing and support phases of gait.

作者:Rudi, Kobetic;E Byron, Marsolais;Ronald J, Triolo;Dwight T, Davy;Richard, Gaudio;Scott, Tashman

来源:The journal of spinal cord medicine 2003 年 26卷 3期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:0
作者:
Rudi, Kobetic;E Byron, Marsolais;Ronald J, Triolo;Dwight T, Davy;Richard, Gaudio;Scott, Tashman
来源:
The journal of spinal cord medicine 2003 年 26卷 3期
The purpose of this case study was to improve stability, posture, and speed of gait in an individual with paraplegia through the application of a hybrid system including trunk-hip-knee-ankle-foot orthosis (THKAFO) with lockable joints and multichannel functional electrical stimulation (FES) with implanted electrodes.Two hybrid orthoses were implemented and evaluated on a person with complete absence of motor function and sensation below the T-9 level spinal cord injury. The first hybrid was a modified isocentric reciprocal gait orthosis (IRGO) with the knees controlled by FES, the ankles fixed at neutral, and the hips coupled with a reciprocator. The second hybrid had a THKAFO instrumented with lockable joints using wrap-spring clutches at the hips and knees (THKAFO-LJ) that provided free extension and allowed for flexion only when disengaged by solenoids. A microprocessor-controlled stimulator provided muscle stimulation and activation signals for the solenoids. These two hybrid systems were compared with an FES-only system.The IRGO hybrid system with the hip reciprocator engaged provided a stable gait with erect posture with minimal anterior trunk lean using only quad canes for support. However, the walking speed was slow, due to limited step length imposed by the reciprocator. The walking speed with the THKAFO-LJ hybrid system was significantly faster than that with the IRGO hybrid with the reciprocator engaged, and was comparable with the FES-only gait; however, it resulted in excessive anterior trunk lean. A walker with 2 wheels was required to maintain balance.The results point to the need for a hybrid system that allows for unencumbered hip and knee joint motion for stepping without excessive anterior trunk lean. Such a hybrid system could provide a reasonable speed in gait powered by muscle stimulation, without the usual joint motion constraints imposed by the bracing, while providing stability that is normally seen only with bracing. Further advantages would include reduction in required stimulation during standing and support phases of gait.