Computer-assisted surgery, which provides simultaneous, multiplanar images of bone structures, has become widely used. However, registration maneuvering remains time consuming. The objective of this paper is to document the usefulness of CT-fluoro matching for spinal navigation. A spinal navigation system (VECTORVISION compact; Brain LAB, Germany) and a digital imaging system (OEC9800; CATHEX, Tokyo, Japan) were used for CT-fluoro matching in cases of L4/5 and L5/S1 posterior lumbar interbody fusion. A reference array was attached to the L4 spinous process. Preoperative CT images and intraoperative fluoro-shots including L4, L5, and S1 were superimposed on the navigation monitor. Following insertion of L4 screws, a reference array remained to be attached to the L4 spinous process, after which a level definition and pre-registration of L5 and S1 vertebrae were performed and the screwing procedure of L5 and S1 was completed without additional fluro-shots. Registration of three vertebrae was completed without paired-point or surface-matching procedures. The calculation time for the registration in a single vertebra was 30 sec. All pedicle screws were seen to be successfully inserted on postoperative CT images. We performed the navigation surgery by matching the preoperative CT images to the intraoperative fluoro-shots without manual registration. This technique may prove useful in the future for anterior spinal surgery and percutaneous screwing without the need for total exposure of the bone surface.

作者:Yoshihito, Sakai;Yukihiro, Matsuyama;Hisatake, Yoshihara;Hiroshi, Nakamura;Shojiro, Nakashima;Naoki, Ishiguro

来源:Nagoya journal of medical science 2006 年 68卷 1-2期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:9
作者:
Yoshihito, Sakai;Yukihiro, Matsuyama;Hisatake, Yoshihara;Hiroshi, Nakamura;Shojiro, Nakashima;Naoki, Ishiguro
来源:
Nagoya journal of medical science 2006 年 68卷 1-2期
Computer-assisted surgery, which provides simultaneous, multiplanar images of bone structures, has become widely used. However, registration maneuvering remains time consuming. The objective of this paper is to document the usefulness of CT-fluoro matching for spinal navigation. A spinal navigation system (VECTORVISION compact; Brain LAB, Germany) and a digital imaging system (OEC9800; CATHEX, Tokyo, Japan) were used for CT-fluoro matching in cases of L4/5 and L5/S1 posterior lumbar interbody fusion. A reference array was attached to the L4 spinous process. Preoperative CT images and intraoperative fluoro-shots including L4, L5, and S1 were superimposed on the navigation monitor. Following insertion of L4 screws, a reference array remained to be attached to the L4 spinous process, after which a level definition and pre-registration of L5 and S1 vertebrae were performed and the screwing procedure of L5 and S1 was completed without additional fluro-shots. Registration of three vertebrae was completed without paired-point or surface-matching procedures. The calculation time for the registration in a single vertebra was 30 sec. All pedicle screws were seen to be successfully inserted on postoperative CT images. We performed the navigation surgery by matching the preoperative CT images to the intraoperative fluoro-shots without manual registration. This technique may prove useful in the future for anterior spinal surgery and percutaneous screwing without the need for total exposure of the bone surface.