Double-pigtail ureteral stent is placed cystoscopically after ureteroscopy. We describe a technique for fluoroscopic placement of ureteral stents and demonstrate its use in a non-randomized prospective study.Double-pigtail stents were placed either fluoroscopically or cystoscopically in 121 consecutive patients. In the fluoroscopic method, the stent was placed over a guide wire using a stent pusher without the use of cystoscopy. Conversely, stents were placed through the working channel of the cystoscope under vision. The procedure, stent length, width, type, method, ureteral dilation, and use of a retrieval string were noted.A wide range of stent sizes were used. The success with fluoroscopic placement of double-pigtail ureteral stents was 100
作者:G L, Chen;D H, Bagley
来源:Diagnostic and therapeutic endoscopy 2001 年 7卷 3-4期