We evaluated kinetic changes of high-sensitivity cardiac troponin T (hs-cTnT) in patients with acute coronary syndrome (ACS) and patients with hs-cTnT increases not due to ACS to rule in or rule out non-ST-segment elevation myocardial infarction (STEMI).hs-cTnT was measured serially in consecutive patients presenting to the emergency department. Patients with ACS who had at least 2 hs-cTnT measurements within 6 h and non-ACS patients with hs-cTnT concentrations above the 99th percentile value (14 ng/L) were enrolled to compare absolute and relative kinetic changes of hs-cTnT.For discrimination of non-STEMI (n=165) in the entire study population (n=784), the absolute δ change with the ROC-optimized value of 9.2 ng/L yielded an area under the curve of 0.898 and was superior to all relative δ changes (P<0.0001). The positive predictive value for the absolute δ change was 48.7
作者:Matthias, Mueller;Moritz, Biener;Mehrshad, Vafaie;Susanne, Doerr;Till, Keller;Stefan, Blankenberg;Hugo A, Katus;Evangelos, Giannitsis
来源:Clinical chemistry 2012 年 58卷 1期