Cerebrospinal fluid (CSF) was examined for bilirubin, an important indicator for diagnosis of subarachnoid hemorrhage (SAH).A multi-wavelength (340, 415, and 460 nm) spectrophotometric assay was developed for the quantitative measurement of bilirubin in CSF, enabling the mathematical correction for absorbance of hemoglobin and proteins. Bilirubin and hemoglobin results were correlated to HPLC and a standard colorimetric assay, respectively. A subset of samples was sent for an absorbance reading at 450 nm following baseline correction. The multi-wavelength bilirubin assay was validated on 70 patients with confirmed SAH and 70 patients with neurologic symptoms who ruled out for SAH.The multi-wavelength spectrophometric assay demonstrated no interferences due to proteins (albumin) up to 30 g/l or oxyhemoglobin up to 260 mg/l. The assay limit of detection was 0.2 mg/l, linear to 20 mg/l, and CVs ranged from 1 to 6

作者:Andrew, Smith;Alan H B, Wu;Kara L, Lynch;Nerissa, Ko;David G, Grenache

来源:Clinica chimica acta; international journal of clinical chemistry 2013 年 424卷

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:74
作者:
Andrew, Smith;Alan H B, Wu;Kara L, Lynch;Nerissa, Ko;David G, Grenache
来源:
Clinica chimica acta; international journal of clinical chemistry 2013 年 424卷
标签:
ARUP AU AUC-ROC Association of Regional University Pathologists Bilirubin CNS CSF CT CV Cerebrospinal fluid HPLC S(y|x) SAH SE SFGH STARD San Francisco General Hospital Studies on Diagnostic Accuracy UCSF UK NEQAS United Kingdom National External Quality Assessment Service University of California, San Francisco Xanthochromia absorbance unit area under the receiver operating characteristic curve central nervous system cerebrospinal fluid coefficient of variance computer-aided tomography high performance liquid chromatography standard deviation of residuals standard error subarachnoid hemorrhage
Cerebrospinal fluid (CSF) was examined for bilirubin, an important indicator for diagnosis of subarachnoid hemorrhage (SAH).A multi-wavelength (340, 415, and 460 nm) spectrophotometric assay was developed for the quantitative measurement of bilirubin in CSF, enabling the mathematical correction for absorbance of hemoglobin and proteins. Bilirubin and hemoglobin results were correlated to HPLC and a standard colorimetric assay, respectively. A subset of samples was sent for an absorbance reading at 450 nm following baseline correction. The multi-wavelength bilirubin assay was validated on 70 patients with confirmed SAH and 70 patients with neurologic symptoms who ruled out for SAH.The multi-wavelength spectrophometric assay demonstrated no interferences due to proteins (albumin) up to 30 g/l or oxyhemoglobin up to 260 mg/l. The assay limit of detection was 0.2 mg/l, linear to 20 mg/l, and CVs ranged from 1 to 6