您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览79

The surgical maze procedure is highly effective in treating symptomatic atrial fibrillation but may have detrimental effects on left atrial (LA) contractile function and compliance.To describe a series of patients presenting with symptomatic pulmonary hypertension due in part to LA dysfunction after surgical maze procedures.This report includes 9 patients who (1) presented to Mayo Clinic (Rochester, MN) between 2008 and 2012 with unexplained dyspnea and pulmonary hypertension after the surgical maze procedure, (2) underwent comprehensive hemodynamic catheterization with transseptal measurement of LA pressure, (3) had large v waves on LA pressure waveforms, and (4) did not have significant mitral valve regurgitation or stenosis or pulmonary vein stenosis.Invasive hemodynamic assessment revealed (1) severe pulmonary hypertension (mean pulmonary pressure 47 ± 6 mm Hg), (2) severe LA hypertension (27 ± 4 mm Hg), (3) giant LA v waves (to 50 ± 8 mm Hg), (4) absence of LA or left ventricular a waves, and (5) blunted x descents (2 ± 1 mm Hg). Left ventricular end-diastolic pressure was also elevated (20 ± 5 mm Hg).Abnormalities in LA compliance and contractility may lead to giant LA v waves and symptomatic pulmonary hypertension after surgical maze procedures. This syndrome should be considered in the differential diagnosis for pulmonary hypertension and underscores the importance of comprehensive hemodynamic catheterization.

作者:Terrence D, Welch;Megan, Coylewright;Brian D, Powell;Samuel J, Asirvatham;Bernard J, Gersh;Joseph A, Dearani;Rick A, Nishimura

来源:Heart rhythm : the official journal of the Heart Rhythm Society 2013 年 10卷 12期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:79
作者:
Terrence D, Welch;Megan, Coylewright;Brian D, Powell;Samuel J, Asirvatham;Bernard J, Gersh;Joseph A, Dearani;Rick A, Nishimura
来源:
Heart rhythm : the official journal of the Heart Rhythm Society 2013 年 10卷 12期
标签:
AF Ablation Atrial fibrillation Heart failure Hemodynamics LA LV Left atrial function NYHA New York Heart Association PHTN Pulmonary hypertension RF atrial fibrillation left atrial/atrium left ventricular pulmonary hypertension radiofrequency
The surgical maze procedure is highly effective in treating symptomatic atrial fibrillation but may have detrimental effects on left atrial (LA) contractile function and compliance.To describe a series of patients presenting with symptomatic pulmonary hypertension due in part to LA dysfunction after surgical maze procedures.This report includes 9 patients who (1) presented to Mayo Clinic (Rochester, MN) between 2008 and 2012 with unexplained dyspnea and pulmonary hypertension after the surgical maze procedure, (2) underwent comprehensive hemodynamic catheterization with transseptal measurement of LA pressure, (3) had large v waves on LA pressure waveforms, and (4) did not have significant mitral valve regurgitation or stenosis or pulmonary vein stenosis.Invasive hemodynamic assessment revealed (1) severe pulmonary hypertension (mean pulmonary pressure 47 ± 6 mm Hg), (2) severe LA hypertension (27 ± 4 mm Hg), (3) giant LA v waves (to 50 ± 8 mm Hg), (4) absence of LA or left ventricular a waves, and (5) blunted x descents (2 ± 1 mm Hg). Left ventricular end-diastolic pressure was also elevated (20 ± 5 mm Hg).Abnormalities in LA compliance and contractility may lead to giant LA v waves and symptomatic pulmonary hypertension after surgical maze procedures. This syndrome should be considered in the differential diagnosis for pulmonary hypertension and underscores the importance of comprehensive hemodynamic catheterization.