To document intraocular measurements and predict intraocular lens (IOL) power specific to the bald eagle.Eleven adult, captive bald eagles.Axial globe length (AGL), anterior chamber depth (ACD), crystalline lens thickness (CLT), and the distance from the cornea to the posterior lens capsule (CPLC) were measured in eight adult bald eagles using B-mode with vector A-mode ultrasound. Keratometry was done on four eagles. Two estimates for postoperative anterior chamber depth (PACD) were obtained from four aphakic eyes from three eagles by measuring from the apex of the anterior cornea to the center of an imaginary line that would connect the remaining edges of the anterior lens capsule across the capsulorhexis (PACD1) and from the apex of the anterior cornea to halfway between the anterior and posterior lens capsule (PACD2). IOL strength was predicted using the Colenbrander, Binkhorst, and Fyodorov theoretical formulas.Mean ± SD biometry for phakic eyes was AGL = 26.57 ± 0.45 mm, ACD = 4.45 ± 0.18 mm, CLT = 5.49 ± 0.14 mm, and CPLC = 10.00 ± 0.33 mm. Mean predicted PACD1 was 6.1 ± 0.66 mm, and PACD2 was 6.4 ± 0.70 mm. Mean horizontal and vertical corneal refractive power was 39.91 ± 0.43 diopters (D) and 40.02 ± 0.08 D, respectively. Calculated IOL power ranged from +16.4 to 17.4 D.Calculations using ultrasonographic biometry, keratometry, and theoretical IOL formulas suggest that the strength of an IOL necessary to return an aphakic bald eagle to emmetropia is between +16.4 and +17.4 D.

作者:Sonia E, Kuhn;Diane V H, Hendrix;Michael P, Jones;Daniel A, Ward;Katherine H, Baine;Stephen R, Franklin

来源:Veterinary ophthalmology 2015 年 18 Suppl 1卷

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:45
作者:
Sonia E, Kuhn;Diane V H, Hendrix;Michael P, Jones;Daniel A, Ward;Katherine H, Baine;Stephen R, Franklin
来源:
Veterinary ophthalmology 2015 年 18 Suppl 1卷
标签:
Haliaeetus leucocephalus avian bald eagle biometry intraocular lens phacoemulsification
To document intraocular measurements and predict intraocular lens (IOL) power specific to the bald eagle.Eleven adult, captive bald eagles.Axial globe length (AGL), anterior chamber depth (ACD), crystalline lens thickness (CLT), and the distance from the cornea to the posterior lens capsule (CPLC) were measured in eight adult bald eagles using B-mode with vector A-mode ultrasound. Keratometry was done on four eagles. Two estimates for postoperative anterior chamber depth (PACD) were obtained from four aphakic eyes from three eagles by measuring from the apex of the anterior cornea to the center of an imaginary line that would connect the remaining edges of the anterior lens capsule across the capsulorhexis (PACD1) and from the apex of the anterior cornea to halfway between the anterior and posterior lens capsule (PACD2). IOL strength was predicted using the Colenbrander, Binkhorst, and Fyodorov theoretical formulas.Mean ± SD biometry for phakic eyes was AGL = 26.57 ± 0.45 mm, ACD = 4.45 ± 0.18 mm, CLT = 5.49 ± 0.14 mm, and CPLC = 10.00 ± 0.33 mm. Mean predicted PACD1 was 6.1 ± 0.66 mm, and PACD2 was 6.4 ± 0.70 mm. Mean horizontal and vertical corneal refractive power was 39.91 ± 0.43 diopters (D) and 40.02 ± 0.08 D, respectively. Calculated IOL power ranged from +16.4 to 17.4 D.Calculations using ultrasonographic biometry, keratometry, and theoretical IOL formulas suggest that the strength of an IOL necessary to return an aphakic bald eagle to emmetropia is between +16.4 and +17.4 D.