您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览48

Positive pressure mechanical ventilation causes rhythmic changes in thoracic pressure and central blood flow. If entrainment occurs, it could be easier for carbon dioxide to enter through a wounded vein during laparoscopic liver lobe resection (LLR). High-frequency jet ventilation (HFJV) is a ventilating method that does not cause pronounced pressure or blood flow changes. This study aimed to investigate whether HFJV could influence the frequency, severity, or duration of gas embolism (GE) during LLR.Twenty-four anaesthetized piglets underwent lobe resection and were randomly assigned to either normal frequency ventilation (NFV) or HFJV (n=12 per group). During resection, a standardized injury to the left hepatic vein was created to increase the risk of GE. Haemodynamic and respiratory variables were monitored. Online blood gas monitoring and transoesophageal echocardiography were used. GE occurrence and severity were graded as 0 (none), 1 (minor), or 2 (major), depending on the echocardiography results.GE duration was shorter in the HFJV group (P=0.008). However, no differences were found between the two groups in the frequency or severity of embolism. Incidence of Grade 2 embolism was less than that found in previous studies and physiological responses to embolism were variable.HFJV shortened the mean duration of GE during LLR and was a feasible ventilation method during the procedure. Individual physiological responses to GE were unpredictable.

作者:D, Fors;K, Eiriksson;A, Waage;D, Arvidsson;S, Rubertsson

来源:British journal of anaesthesia 2014 年 113卷 3期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:48
作者:
D, Fors;K, Eiriksson;A, Waage;D, Arvidsson;S, Rubertsson
来源:
British journal of anaesthesia 2014 年 113卷 3期
标签:
animal model gas embolism high frequency jet ventilation laparoscopic liver resection
Positive pressure mechanical ventilation causes rhythmic changes in thoracic pressure and central blood flow. If entrainment occurs, it could be easier for carbon dioxide to enter through a wounded vein during laparoscopic liver lobe resection (LLR). High-frequency jet ventilation (HFJV) is a ventilating method that does not cause pronounced pressure or blood flow changes. This study aimed to investigate whether HFJV could influence the frequency, severity, or duration of gas embolism (GE) during LLR.Twenty-four anaesthetized piglets underwent lobe resection and were randomly assigned to either normal frequency ventilation (NFV) or HFJV (n=12 per group). During resection, a standardized injury to the left hepatic vein was created to increase the risk of GE. Haemodynamic and respiratory variables were monitored. Online blood gas monitoring and transoesophageal echocardiography were used. GE occurrence and severity were graded as 0 (none), 1 (minor), or 2 (major), depending on the echocardiography results.GE duration was shorter in the HFJV group (P=0.008). However, no differences were found between the two groups in the frequency or severity of embolism. Incidence of Grade 2 embolism was less than that found in previous studies and physiological responses to embolism were variable.HFJV shortened the mean duration of GE during LLR and was a feasible ventilation method during the procedure. Individual physiological responses to GE were unpredictable.