您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览38

To assess implant:suprastructure misfit in patients with an edentulous jaw restored by an implant-retained fixed dental prosthesis (FDP) and its association with biologic and mechanical adverse events over an extensive period.Thirty patients with an edentulous mandible treated with implant-supported prosthetics before 2000 were examined clinically in 2012. Each patient had received 4 to 6 implants to retain a FDP made from acrylic and three different metal alloys, that is, Ag-Pd, Pd-Ag, and Au type IV. The implant intra-oral locations were recorded digitally by use of an intra-oral scanner, and the intaglio surface of the detached FDP was recorded using a desktop scanner. The fit was estimated by digital matching of the STL files using industrial metrological software. The average misfit was correlated with the average marginal bone loss and the prevalence of screw loosening or fractures, using the patient as the statistical unit.Over an average of 19 years (range 12 to 32), 5 implants had been lost in 4 participants (96.7

作者:Asbj?rn, Jokstad;Babak, Shokati

来源:Clinical oral implants research 2015 年 26卷 10期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:38
作者:
Asbj?rn, Jokstad;Babak, Shokati
来源:
Clinical oral implants research 2015 年 26卷 10期
标签:
3D measurement 3D scanner intra-oral digital optical impression
To assess implant:suprastructure misfit in patients with an edentulous jaw restored by an implant-retained fixed dental prosthesis (FDP) and its association with biologic and mechanical adverse events over an extensive period.Thirty patients with an edentulous mandible treated with implant-supported prosthetics before 2000 were examined clinically in 2012. Each patient had received 4 to 6 implants to retain a FDP made from acrylic and three different metal alloys, that is, Ag-Pd, Pd-Ag, and Au type IV. The implant intra-oral locations were recorded digitally by use of an intra-oral scanner, and the intaglio surface of the detached FDP was recorded using a desktop scanner. The fit was estimated by digital matching of the STL files using industrial metrological software. The average misfit was correlated with the average marginal bone loss and the prevalence of screw loosening or fractures, using the patient as the statistical unit.Over an average of 19 years (range 12 to 32), 5 implants had been lost in 4 participants (96.7