26 European centres participated in a concerted research action Biomedical Engineering: Quantitative Assessment of Osteoporosis. With a newly designed European spine and forearm phantom, the stability, accuracy, precision of dual energy absorption (DXA) and quantitative computer tomography (QCT) densitometry machines have been evaluated. Marked and clinically significant differences were found between brands and between techniques. Cross-calibration formulae have been made and normative data evaluated for different regions (spine, femoral neck, femoral trochanteric and forearm). A general fit for all data obtained from different machines was established.The cross-calibration formulae will allow a sensitivity analysis to assist the choice of equipment for clinical management of different categories of patients with bone disease. The present results obtained with an internationally accepted European spine and forearm phantom can now serve to stimulate the manufacturers to improve the comparability of bone measurements between machines.

作者:J, Dequeker;J, Reeve;J, Pearson;J, Bright;D, Felsenberg;W, Kalender;C, Langton;A M, Laval-Jeantet;P, Rüegsegger;G, Van der Perre

来源:Technology and health care : official journal of the European Society for Engineering and Medicine 1993 年 1卷 2期

相似文献
知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:36
作者:
J, Dequeker;J, Reeve;J, Pearson;J, Bright;D, Felsenberg;W, Kalender;C, Langton;A M, Laval-Jeantet;P, Rüegsegger;G, Van der Perre
来源:
Technology and health care : official journal of the European Society for Engineering and Medicine 1993 年 1卷 2期
标签:
Bone densitometry DXA Osteoporosis QCT
26 European centres participated in a concerted research action Biomedical Engineering: Quantitative Assessment of Osteoporosis. With a newly designed European spine and forearm phantom, the stability, accuracy, precision of dual energy absorption (DXA) and quantitative computer tomography (QCT) densitometry machines have been evaluated. Marked and clinically significant differences were found between brands and between techniques. Cross-calibration formulae have been made and normative data evaluated for different regions (spine, femoral neck, femoral trochanteric and forearm). A general fit for all data obtained from different machines was established.The cross-calibration formulae will allow a sensitivity analysis to assist the choice of equipment for clinical management of different categories of patients with bone disease. The present results obtained with an internationally accepted European spine and forearm phantom can now serve to stimulate the manufacturers to improve the comparability of bone measurements between machines.