Due to lack of reliable imaging contrast from catheter radiofrequency ablation (RFA) lesions, the vast majority of current procedures rely on indirect indicators of ablation activity, resulting in a significant number of arrhythmia reoccurrences after RFA procedures and the need for repeat surgeries. The objective of this work is to develop an accurate method for on-the-fly assessment of the durability and size of lesions formed during RFA procedures.Radiofrequency catheter ablation on freshly excised porcine ventricular myocardial tissue was optoacoustically monitored by means of pulsed-laser illumination in the near-infrared spectrum. Lesion formation during ablation was captured at a rate of 10 Hz with a 256-detector optoacoustic imaging probe. Postablated samples were imaged using multispectral excitation in the wavelength range 740-860 nm to determine the lesion contrast spectrum. Tomographic reconstruction was performed to generate 3-dimensional images of the lesions, which were compared to photographs depicting the final ablated tissue samples. Video-rate 3-dimensional tomographic reconstructions depict formation of the lesion with high contrast and spatial resolution. The size and geometry of the lesion was shown to be in excellent agreement with the histological examinations. The wavelength dependence of the lesion contrast shows a contrast peak near 780 nm.Deep-tissue 3-dimensional monitoring of RFA lesion generation in real time was demonstrated for the first time in this work. The results suggest the potential of optoacoustic monitoring for providing critical feedback on lesion position and size during radiofrequency catheter ablation, improving safety and efficacy of these treatments.

作者:Genny A, Pang;Erwin, Bay;X Luís, Deán-Ben;Daniel, Razansky

来源:Journal of cardiovascular electrophysiology 2015 年 26卷 3期

相似文献
知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:57
作者:
Genny A, Pang;Erwin, Bay;X Luís, Deán-Ben;Daniel, Razansky
来源:
Journal of cardiovascular electrophysiology 2015 年 26卷 3期
标签:
catheter ablation imaging optoacoustic photoacoustic real-time tomography
Due to lack of reliable imaging contrast from catheter radiofrequency ablation (RFA) lesions, the vast majority of current procedures rely on indirect indicators of ablation activity, resulting in a significant number of arrhythmia reoccurrences after RFA procedures and the need for repeat surgeries. The objective of this work is to develop an accurate method for on-the-fly assessment of the durability and size of lesions formed during RFA procedures.Radiofrequency catheter ablation on freshly excised porcine ventricular myocardial tissue was optoacoustically monitored by means of pulsed-laser illumination in the near-infrared spectrum. Lesion formation during ablation was captured at a rate of 10 Hz with a 256-detector optoacoustic imaging probe. Postablated samples were imaged using multispectral excitation in the wavelength range 740-860 nm to determine the lesion contrast spectrum. Tomographic reconstruction was performed to generate 3-dimensional images of the lesions, which were compared to photographs depicting the final ablated tissue samples. Video-rate 3-dimensional tomographic reconstructions depict formation of the lesion with high contrast and spatial resolution. The size and geometry of the lesion was shown to be in excellent agreement with the histological examinations. The wavelength dependence of the lesion contrast shows a contrast peak near 780 nm.Deep-tissue 3-dimensional monitoring of RFA lesion generation in real time was demonstrated for the first time in this work. The results suggest the potential of optoacoustic monitoring for providing critical feedback on lesion position and size during radiofrequency catheter ablation, improving safety and efficacy of these treatments.