您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览16

A novel electrogenerated chemiluminescence (ECL) biosensor was built for the detection of kinase activity based on multiple signal amplification nanoprobes. In this strategy, the Xanthine oxidase (XOD) and 5'-phosphate group end DNA conjugated AuNPs was integrated with the phosphorylated peptide by Zr(4+). The XOD on gold nanoparticles can catalyze dissolved oxygen to produce H2O2 in the presence of hypoxanthine (HA) which acts as a coreactor for luminol ECL reaction. In addition, due to the excellent catalytic activity of gold nanoparticle toward luminol ECL reaction and its large surface area that can accommodate large number of XOD and DNA on the surface, the ECL signal of luminol was significantly amplified, affording a highly sensitive ECL analysis of kinase activity. The as-proposed biosensor presents a low detection limit of 0.09 U mL(-1) for protein kinase A (PKA) activity, wide linear range (from 0.1 to 10 U mL(-1)) and excellent stability even in serum samples. This biosensor can also be applied for quantitative kinase inhibitor evaluation. The robust ECL biosensor provides a valuable tool for the high throughput assay in the applications of clinic diagnostic and therapeutic.

作者:Zonghua, Wang;Zhiyong, Yan;Na, Sun;Yang, Liu

来源:Biosensors & bioelectronics 2015 年 68卷

相似文献
知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:16
作者:
Zonghua, Wang;Zhiyong, Yan;Na, Sun;Yang, Liu
来源:
Biosensors & bioelectronics 2015 年 68卷
标签:
Electrogenerated chemiluminescence Enzyme Gold nanoparticle Kinase Phosphorylation
A novel electrogenerated chemiluminescence (ECL) biosensor was built for the detection of kinase activity based on multiple signal amplification nanoprobes. In this strategy, the Xanthine oxidase (XOD) and 5'-phosphate group end DNA conjugated AuNPs was integrated with the phosphorylated peptide by Zr(4+). The XOD on gold nanoparticles can catalyze dissolved oxygen to produce H2O2 in the presence of hypoxanthine (HA) which acts as a coreactor for luminol ECL reaction. In addition, due to the excellent catalytic activity of gold nanoparticle toward luminol ECL reaction and its large surface area that can accommodate large number of XOD and DNA on the surface, the ECL signal of luminol was significantly amplified, affording a highly sensitive ECL analysis of kinase activity. The as-proposed biosensor presents a low detection limit of 0.09 U mL(-1) for protein kinase A (PKA) activity, wide linear range (from 0.1 to 10 U mL(-1)) and excellent stability even in serum samples. This biosensor can also be applied for quantitative kinase inhibitor evaluation. The robust ECL biosensor provides a valuable tool for the high throughput assay in the applications of clinic diagnostic and therapeutic.