您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览24

Inexperienced physicians frequently have difficulty performing nasal fiberoptic intubation. A pre-inserted tracheal tube of the appropriate length allows an excellent view of the laryngeal opening. The purpose of this study was to determine the ideal length of a pre-inserted tracheal tube for nasal fiberoptic intubation and to investigate if it could be predicted from easily measureable patient parameters.This was an observational study in which data on adult patients (n = 150) requiring nasal intubation were collected and analyzed by stepwise regression. During the pre-anesthesia examination, a right-angled gauge was used to measure the distance from the mid-point of the lateral border of the nares to the tragus of the ear (NT distance) and to the mandibular angle (NM distance). The distance from the tragus to the mandibular angle (TM distance) was also measured. The age, sex, height, and weight of each patient were recorded. After induction of anesthesia, the minimum and maximum lengths of the pre-inserted tracheal tube that provided an excellent view of laryngeal opening during nasal fiberoptic intubation were measured. The optimal length was calculated, and an equation was derived through stepwise regression analysis.The optimal length for each patient could be reliably predicted using the equation (distances in cm, weight in kg): optimal length (cm) = 1.952 + 0.051 × height (cm) + 0.354 × NM distance (cm) - 0.011 × weight (kg) (r (2) = 0.460, P < 0.001).The optimal length of pre-inserted tracheal tube for nasal fiberoptic intubation can be predicted using a newly developed formula with three patient parameters, namely, height, the NM distance, and weight. Application of this equation in the clinical setting should facilitate nasal fiberoptic intubation.

作者:Jiwon, Lee;Jung-Man, Lee;Jeong Jin, Min;Chang-Hoon, Koo;Hyun Jeong, Kim

来源:Journal of anesthesia 2016 年 30卷 2期

相似文献
知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:24
作者:
Jiwon, Lee;Jung-Man, Lee;Jeong Jin, Min;Chang-Hoon, Koo;Hyun Jeong, Kim
来源:
Journal of anesthesia 2016 年 30卷 2期
标签:
Airway management Bronchoscope Fiberoptic intubation Laryngeal opening Tracheal tube
Inexperienced physicians frequently have difficulty performing nasal fiberoptic intubation. A pre-inserted tracheal tube of the appropriate length allows an excellent view of the laryngeal opening. The purpose of this study was to determine the ideal length of a pre-inserted tracheal tube for nasal fiberoptic intubation and to investigate if it could be predicted from easily measureable patient parameters.This was an observational study in which data on adult patients (n = 150) requiring nasal intubation were collected and analyzed by stepwise regression. During the pre-anesthesia examination, a right-angled gauge was used to measure the distance from the mid-point of the lateral border of the nares to the tragus of the ear (NT distance) and to the mandibular angle (NM distance). The distance from the tragus to the mandibular angle (TM distance) was also measured. The age, sex, height, and weight of each patient were recorded. After induction of anesthesia, the minimum and maximum lengths of the pre-inserted tracheal tube that provided an excellent view of laryngeal opening during nasal fiberoptic intubation were measured. The optimal length was calculated, and an equation was derived through stepwise regression analysis.The optimal length for each patient could be reliably predicted using the equation (distances in cm, weight in kg): optimal length (cm) = 1.952 + 0.051 × height (cm) + 0.354 × NM distance (cm) - 0.011 × weight (kg) (r (2) = 0.460, P < 0.001).The optimal length of pre-inserted tracheal tube for nasal fiberoptic intubation can be predicted using a newly developed formula with three patient parameters, namely, height, the NM distance, and weight. Application of this equation in the clinical setting should facilitate nasal fiberoptic intubation.