Aortic valve replacement (AVR) with sutureless bioprostheses has become an alternative to conventional AVR for patients with intermediate to high operative risk. However, this technique is associated with an increased risk of postoperative conduction disorders.We analysed 258 patients who underwent AVR with the Perceval prosthesis from July 2010 to September 2014 at our centre. Electrocardiography were obtained at baseline to record preoperatively the presence of conduction disorders. Preoperative risk factors, intraoperative procedures and complications (61 variables) were compared between patients with permanent pacemaker (PPM group) and without (no-PPM group) need for postoperative PPM implantation.One hundred and sixty-nine patients underwent isolated AVR with the Perceval bioprosthesis, 89 patients had associated surgery and 23 patients underwent redo operations. The mean age was 77.7 ± 5 years, 139 patients were female (46
作者:Ferdinand, Vogt;Steffen, Pfeiffer;Angelo Maria, Dell'Aquila;Theodor, Fischlein;Giuseppe, Santarpino
来源:Interactive cardiovascular and thoracic surgery 2016 年 22卷 3期