您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览25

To investigate the effect of femtosecond laser-assisted cataract surgery (FLACS) on aqueous humour and lens capsule.This prospective randomized comparative study enrolled 19 eyes that underwent FLACS as the trial group and 20 eyes that underwent conventional phacoemulsification as the control group. The femtosecond laser platform (LLS-fs 3D; LensAR, Orlando, FL, USA) was used to generate capsulotomy (laser energy 8 μJ) and lens fragmentation (laser energy 10 μJ). Morphology of the cutting edge and cells of anterior capsule was assessed by light microscopy. The proteins in the aqueous humour were identified by mass spectrometry (Ultraflex III TOF/TOF; Bruker Dalton, Bremen, Germany). Electrolyte in the aqueous humour was detected by a chemistry analyzer (Aeroset Clinical Chemistry Analyzer; Abbott Laboratories, Abbott Park, IL, USA).The cutting edge of anterior capsule was saw-tooth-shaped under magnification of 200× and 400× in the trial group, while it was smooth in the control group. Intact cells were found in the boundary area next to the cutting edge of anterior capsule in both groups. β-Crystallin B1, γ-crystallin S and transferrin were detected in the aqueous humour in the trial group. The concentrations of K+ , Na+ and Cl- in the aqueous humour in the trial group differed significantly from those in the control group (p = 0.02, 0.03 and 0.04, respectively).Femtosecond laser-assisted cataract surgery (FLACS) causes release of transferrin and crystallin from lens to aqueous humour and results in significant changes in the concentrations of K+ , Na+ and Cl- in aqueous humour. However, these changes due to FLACS have no clinical significance or toxicity.

作者:A-Yong, Yu;Cai-Xia, Lin;Qin-Mei, Wang;Mei-Qing, Zheng;Xiao-Yi, Qin

来源:Acta ophthalmologica 2016 年 94卷 7期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:25
作者:
A-Yong, Yu;Cai-Xia, Lin;Qin-Mei, Wang;Mei-Qing, Zheng;Xiao-Yi, Qin
来源:
Acta ophthalmologica 2016 年 94卷 7期
标签:
aqueous humour cataract femtosecond laser lens capsule
To investigate the effect of femtosecond laser-assisted cataract surgery (FLACS) on aqueous humour and lens capsule.This prospective randomized comparative study enrolled 19 eyes that underwent FLACS as the trial group and 20 eyes that underwent conventional phacoemulsification as the control group. The femtosecond laser platform (LLS-fs 3D; LensAR, Orlando, FL, USA) was used to generate capsulotomy (laser energy 8 μJ) and lens fragmentation (laser energy 10 μJ). Morphology of the cutting edge and cells of anterior capsule was assessed by light microscopy. The proteins in the aqueous humour were identified by mass spectrometry (Ultraflex III TOF/TOF; Bruker Dalton, Bremen, Germany). Electrolyte in the aqueous humour was detected by a chemistry analyzer (Aeroset Clinical Chemistry Analyzer; Abbott Laboratories, Abbott Park, IL, USA).The cutting edge of anterior capsule was saw-tooth-shaped under magnification of 200× and 400× in the trial group, while it was smooth in the control group. Intact cells were found in the boundary area next to the cutting edge of anterior capsule in both groups. β-Crystallin B1, γ-crystallin S and transferrin were detected in the aqueous humour in the trial group. The concentrations of K+ , Na+ and Cl- in the aqueous humour in the trial group differed significantly from those in the control group (p = 0.02, 0.03 and 0.04, respectively).Femtosecond laser-assisted cataract surgery (FLACS) causes release of transferrin and crystallin from lens to aqueous humour and results in significant changes in the concentrations of K+ , Na+ and Cl- in aqueous humour. However, these changes due to FLACS have no clinical significance or toxicity.