Vacuum-assisted venous drainage (VAVD) is widely used to enhance venous blood return from patients undergoing cardiopulmonary bypass (CPB). This vacuum can accidentally reach the oxygenator of the heart-lung machine and draw gas bubbles into the blood. This is known as bubble transgression (BT) and may cause air emboli in the arterial blood line. In order to avoid BT and minimize the risk of patient injury, knowledge of oxygenator tolerance to vacuum load is critical. Thus, the main aim of this thesis was to investigate how much vacuum a membrane oxygenator can withstand before BT appears.We investigated four different adult oxygenators: Quadrox-i, Affinity Fusion, Capiox RX25 and Inspire 6M. They were tested in an in vitro setup where VAVD vacuum was allowed to reach the oxygenator through a non-occlusive roller pump. An ultrasonic clinical bubble counter, Gampt BCC 200, was used to count bubbles on the arterial line when the arterial pump was restarted.We observed a significant increase in bubble count for two of the oxygenators, caused by -30 mmHg of VAVD vacuum in the blood reservoir (Affinity Fusion and Inspire 6M). Massive air ingress was shown in two of the oxygenators, caused by -30 mmHg of VAVD vacuum in the reservoir (Capiox RX25) and -40 mmHg of VAVD vacuum in the reservoir (Affinity Fusion).VAVD vacuum may cause bubble transgression in an oxygenator. This was shown for all the oxygenators in this test. VAVD vacuum may cause visible massive air ingress in an oxygenator. This was shown for two of the oxygenators in this test (Capiox RX25 and Affinity Fusion). An alarm triggering on negative pressure in the oxygenator or a pressure relief valve might improve safety when using VAVD.

作者:K, Nygaard;A S, Thiara;C, Tronstad;M A, Ringdal;A E, Fiane

来源:Perfusion 2016 年

相似文献
知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:56
作者:
K, Nygaard;A S, Thiara;C, Tronstad;M A, Ringdal;A E, Fiane
来源:
Perfusion 2016 年
标签:
VAVD air emboli bubble transgression cardiopulmonary bypass gaseous microemboli membrane oxygenator vacuum-assisted venous drainage
Vacuum-assisted venous drainage (VAVD) is widely used to enhance venous blood return from patients undergoing cardiopulmonary bypass (CPB). This vacuum can accidentally reach the oxygenator of the heart-lung machine and draw gas bubbles into the blood. This is known as bubble transgression (BT) and may cause air emboli in the arterial blood line. In order to avoid BT and minimize the risk of patient injury, knowledge of oxygenator tolerance to vacuum load is critical. Thus, the main aim of this thesis was to investigate how much vacuum a membrane oxygenator can withstand before BT appears.We investigated four different adult oxygenators: Quadrox-i, Affinity Fusion, Capiox RX25 and Inspire 6M. They were tested in an in vitro setup where VAVD vacuum was allowed to reach the oxygenator through a non-occlusive roller pump. An ultrasonic clinical bubble counter, Gampt BCC 200, was used to count bubbles on the arterial line when the arterial pump was restarted.We observed a significant increase in bubble count for two of the oxygenators, caused by -30 mmHg of VAVD vacuum in the blood reservoir (Affinity Fusion and Inspire 6M). Massive air ingress was shown in two of the oxygenators, caused by -30 mmHg of VAVD vacuum in the reservoir (Capiox RX25) and -40 mmHg of VAVD vacuum in the reservoir (Affinity Fusion).VAVD vacuum may cause bubble transgression in an oxygenator. This was shown for all the oxygenators in this test. VAVD vacuum may cause visible massive air ingress in an oxygenator. This was shown for two of the oxygenators in this test (Capiox RX25 and Affinity Fusion). An alarm triggering on negative pressure in the oxygenator or a pressure relief valve might improve safety when using VAVD.