您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览17

The aims of this study was first to investigate whether the bite size or the bite distance from the tear edge is of primary importance in mattress suture configuration for rotator cuff repair. Secondly, whether the use of a 450 left side bent Arthro-Pierce™ (Smith & Nephew, Andover, USA) during suture passage can be more effective on the strength of the configuration compared to a straight Arthro-Pierce™.Twenty-eight bovine infraspinatus muscle tendons were randomized into four groups. Group 1; 5 mm wide 'bite size' × 15 mm length 'distance from the tear edge's mattress'; Group 2: 7.5 mm × 10 mm; Group 3: 15 mm × 5 mm 'using straight Arthro-Pierce™' and Group 4: 5 mm × 15 mm using left sided 450 bent Arthro-Pierce™. The repair specimens underwent cyclic loading prior to loading the failure testing. Cyclic elongation (mm), peak-to-peak displacement (mm), ultimate load (N), stiffness (N/mm) and failure mode were recorded for each specimen.The mean ultimate load in Group 1 was higher compared to group 3. The peak to peak displacement was higher in Group 4 compared to Group 1 (p < 0.05). The predominant failure mode in Groups 1, 2 and 4 was suture rupture. The Group 3 most specimens failed due to suture cut through the tendon.Bite size from the edge of the tendon seems to be more important than the width of the mattress. The curve of the suture passing device may also have an effect on the strength of the suture tendon interface.

作者:Onur, Hapa;Ahmet, Karaka?l?;Onur, Ba???;Hakan, Cici;Berivan, ?e?en;Hasan, Havit?io?lu

来源:Acta orthopaedica et traumatologica turcica 2016 年 50卷 4期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:17
作者:
Onur, Hapa;Ahmet, Karaka?l?;Onur, Ba???;Hakan, Cici;Berivan, ?e?en;Hasan, Havit?io?lu
来源:
Acta orthopaedica et traumatologica turcica 2016 年 50卷 4期
标签:
Mattress repair Rotator cuff tear
The aims of this study was first to investigate whether the bite size or the bite distance from the tear edge is of primary importance in mattress suture configuration for rotator cuff repair. Secondly, whether the use of a 450 left side bent Arthro-Pierce™ (Smith & Nephew, Andover, USA) during suture passage can be more effective on the strength of the configuration compared to a straight Arthro-Pierce™.Twenty-eight bovine infraspinatus muscle tendons were randomized into four groups. Group 1; 5 mm wide 'bite size' × 15 mm length 'distance from the tear edge's mattress'; Group 2: 7.5 mm × 10 mm; Group 3: 15 mm × 5 mm 'using straight Arthro-Pierce™' and Group 4: 5 mm × 15 mm using left sided 450 bent Arthro-Pierce™. The repair specimens underwent cyclic loading prior to loading the failure testing. Cyclic elongation (mm), peak-to-peak displacement (mm), ultimate load (N), stiffness (N/mm) and failure mode were recorded for each specimen.The mean ultimate load in Group 1 was higher compared to group 3. The peak to peak displacement was higher in Group 4 compared to Group 1 (p < 0.05). The predominant failure mode in Groups 1, 2 and 4 was suture rupture. The Group 3 most specimens failed due to suture cut through the tendon.Bite size from the edge of the tendon seems to be more important than the width of the mattress. The curve of the suture passing device may also have an effect on the strength of the suture tendon interface.