您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览22

Endoscopes represent the medical devices most commonly linked to health care-associated outbreaks and pseudo-outbreaks. Most of the recent outbreaks and pseudo-outbreaks have resulted from contaminated automated endoscope reprocessors (AER) or the use of damaged or malfunctioning bronchoscopes or contaminated equipment.We investigated a pseudo-outbreak of Pseudomonas putida and Stenotrophomonas maltophilia recovered from bronchial washing (BW) specimens obtained during bronchoscopy in a bronchoscopy unit.Samples were obtained from environmental surfaces in the endoscopy suite, bronchoscopes, and bronchoscopic dispensable material, and specimens of cleaning solutions, cleaning brushes, the AER, and the ultrasound system were sent for bacterial culture. Medical records were reviewed to identify possible infections after a bronchoscopy.P. putida and S. maltophilia were isolated from BW samples of 39 patients. The bronchoscopy models Olympus BF-1T160 and BF-160 were contaminated. Both bronchoscopes and other contaminated material (cleaning brushes, diluted cleaning solutions, and the sink) were isolated, but new cases continued to appear. The AER was recently installed, and new connections were used for the water lines and new tubes were connected to the AER. Initially, specimens were obtained from the external circuits and the internal walls of the AER. Finally, cultures were made from the filters on the water lines, and growth of P. putida and S. maltophilia was found. The investigation revealed that the BW specimens were contaminated because sterile saline was injected by means of the biopsy port of the bronchoscope and was recovered through the same channel by means of the proximal suction port. No patients developed clinical signs or symptoms of infection, but the positive cultures did lead to treatment of 21 patients.We described a pseudo-outbreak related to a contaminated bronchoscope because of inadequate installation of the AER for used new water lines and because the new tubes were connected to the AER. The antibacterial filters of the AER used tap water, and this may have contained low levels of microorganisms. No serious clinical complications derived from this pseudo-outbreak.

作者:Maribel, Botana-Rial;Virginia, Leiro-Fernández;Manuel, Nú?ez-Delgado;Maximiliano, álvarez-Fernández;Susana, Otero-Fernández;Helena, Bello-Rodríguez;Carlos, Vilari?o-Pombo;Alberto, Fernández-Villar

来源:Respiration; international review of thoracic diseases 2016 年 92卷 4期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:22
作者:
Maribel, Botana-Rial;Virginia, Leiro-Fernández;Manuel, Nú?ez-Delgado;Maximiliano, álvarez-Fernández;Susana, Otero-Fernández;Helena, Bello-Rodríguez;Carlos, Vilari?o-Pombo;Alberto, Fernández-Villar
来源:
Respiration; international review of thoracic diseases 2016 年 92卷 4期
Endoscopes represent the medical devices most commonly linked to health care-associated outbreaks and pseudo-outbreaks. Most of the recent outbreaks and pseudo-outbreaks have resulted from contaminated automated endoscope reprocessors (AER) or the use of damaged or malfunctioning bronchoscopes or contaminated equipment.We investigated a pseudo-outbreak of Pseudomonas putida and Stenotrophomonas maltophilia recovered from bronchial washing (BW) specimens obtained during bronchoscopy in a bronchoscopy unit.Samples were obtained from environmental surfaces in the endoscopy suite, bronchoscopes, and bronchoscopic dispensable material, and specimens of cleaning solutions, cleaning brushes, the AER, and the ultrasound system were sent for bacterial culture. Medical records were reviewed to identify possible infections after a bronchoscopy.P. putida and S. maltophilia were isolated from BW samples of 39 patients. The bronchoscopy models Olympus BF-1T160 and BF-160 were contaminated. Both bronchoscopes and other contaminated material (cleaning brushes, diluted cleaning solutions, and the sink) were isolated, but new cases continued to appear. The AER was recently installed, and new connections were used for the water lines and new tubes were connected to the AER. Initially, specimens were obtained from the external circuits and the internal walls of the AER. Finally, cultures were made from the filters on the water lines, and growth of P. putida and S. maltophilia was found. The investigation revealed that the BW specimens were contaminated because sterile saline was injected by means of the biopsy port of the bronchoscope and was recovered through the same channel by means of the proximal suction port. No patients developed clinical signs or symptoms of infection, but the positive cultures did lead to treatment of 21 patients.We described a pseudo-outbreak related to a contaminated bronchoscope because of inadequate installation of the AER for used new water lines and because the new tubes were connected to the AER. The antibacterial filters of the AER used tap water, and this may have contained low levels of microorganisms. No serious clinical complications derived from this pseudo-outbreak.