To evaluate the long-term effectiveness and safety of the adjustable transobturator male system (ATOMS® , Agency for Medical Innovations A.M.I., Feldkirch, Austria) in a European-wide multicentre setting.In all, 287 men with stress urinary incontinence (SUI) were treated with the ATOMS device between June 2009 and March 2016. Continence parameters (daily pad test/pad use), urodynamics (maximum urinary flow rate, voiding volume, residual urine), and pain/quality of life (QoL) ratings (visual analogue scale/Leeds Assessment of Neuropathic Symptoms and Signs, International Consultation on Incontinence Questionnaire-Short Form [ICIQ-SF]/Patient Global Impression of Improvement [PGI-I]) were compared preoperatively and after intermediate (12 months) as well as after individual maximum follow-up. Overall success rate, dry rate (<10 mL/day and 0-1 pad/day), device durability, treatment failure, and device complications were recorded. Nonparametric tests were used for statistical analyses.After a median (interquartile range [IQR]) follow-up of 31 (10-54) months and a median (IQR) of 3 (2-4) adjustments, the overall success rate was 90

作者:Alexander, Friedl;Sandra, Mühlst?dt;Roman, Zachoval;Alessandro, Giammò;Danijel, Kivaranovic;Maximilian, Rom;Paolo, Fornara;Clemens, Br?ssner

来源:BJU international 2016 年

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:54
作者:
Alexander, Friedl;Sandra, Mühlst?dt;Roman, Zachoval;Alessandro, Giammò;Danijel, Kivaranovic;Maximilian, Rom;Paolo, Fornara;Clemens, Br?ssner
来源:
BJU international 2016 年
标签:
adjustable transobturator male system continence device efficacy long-term outcome male stress urinary incontinence quality of life
To evaluate the long-term effectiveness and safety of the adjustable transobturator male system (ATOMS® , Agency for Medical Innovations A.M.I., Feldkirch, Austria) in a European-wide multicentre setting.In all, 287 men with stress urinary incontinence (SUI) were treated with the ATOMS device between June 2009 and March 2016. Continence parameters (daily pad test/pad use), urodynamics (maximum urinary flow rate, voiding volume, residual urine), and pain/quality of life (QoL) ratings (visual analogue scale/Leeds Assessment of Neuropathic Symptoms and Signs, International Consultation on Incontinence Questionnaire-Short Form [ICIQ-SF]/Patient Global Impression of Improvement [PGI-I]) were compared preoperatively and after intermediate (12 months) as well as after individual maximum follow-up. Overall success rate, dry rate (<10 mL/day and 0-1 pad/day), device durability, treatment failure, and device complications were recorded. Nonparametric tests were used for statistical analyses.After a median (interquartile range [IQR]) follow-up of 31 (10-54) months and a median (IQR) of 3 (2-4) adjustments, the overall success rate was 90