您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览25

The porous silicon (PS) surface modification diagnostics due to functionalization and water adsorption/desorption processes were provided by the self-action effects of picosecond range pulsed laser radiation at 1064 nm. It was shown that the PS surface functionalization-oxide removal, alkylation, and oxidation-resulted in a refractive nonlinear optical (NLO) response sign turn to self-focusing (Δn>0) versus the self-defocusing (Δn<0) observed in the aged PS. The sensitivity of the proposed technique was revealed to water adsorption/desorption from the chemically oxidized PS interface. For the dried PS, the self-defocusing effect with corresponding NLO cubic susceptibility Re(χ (3))∼-4.7·10-9 esu was observed versus the self-focusing one (∼5·10-8 esu) for the PS positioned in saturated water vapor at room temperature. The obtained results demonstrate high sensitivity and wide versatility of the proposed readout technique based on pulsed laser radiation self-action at 1064 nm to the PS surface modification monitoring/diagnostics applications.

作者:Andrii V, Uklein;Volodymyr V, Multian;Bogdan V, Oliinyk;Volodymyr V, Doroshchuk;Sergei A, Alekseev;Volodymyr V, Lysenko;Mykhailo S, Brodyn;Volodymyr Ya, Gayvoronsky

来源:Nanoscale research letters 2017 年 12卷 1期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:25
作者:
Andrii V, Uklein;Volodymyr V, Multian;Bogdan V, Oliinyk;Volodymyr V, Doroshchuk;Sergei A, Alekseev;Volodymyr V, Lysenko;Mykhailo S, Brodyn;Volodymyr Ya, Gayvoronsky
来源:
Nanoscale research letters 2017 年 12卷 1期
标签:
Nonlinear optical response Porous silicon functionalization Surface diagnostics Water adsorption/desorption
The porous silicon (PS) surface modification diagnostics due to functionalization and water adsorption/desorption processes were provided by the self-action effects of picosecond range pulsed laser radiation at 1064 nm. It was shown that the PS surface functionalization-oxide removal, alkylation, and oxidation-resulted in a refractive nonlinear optical (NLO) response sign turn to self-focusing (Δn>0) versus the self-defocusing (Δn<0) observed in the aged PS. The sensitivity of the proposed technique was revealed to water adsorption/desorption from the chemically oxidized PS interface. For the dried PS, the self-defocusing effect with corresponding NLO cubic susceptibility Re(χ (3))∼-4.7·10-9 esu was observed versus the self-focusing one (∼5·10-8 esu) for the PS positioned in saturated water vapor at room temperature. The obtained results demonstrate high sensitivity and wide versatility of the proposed readout technique based on pulsed laser radiation self-action at 1064 nm to the PS surface modification monitoring/diagnostics applications.