One complication associated with the refill procedure of intrathecal drug delivery systems (IDDSs) include a "pocket fill," which is the inadvertent injection of the drug into the subcutaneous space surrounding the pump. The purpose of our study was to assess the mean volume discrepancy between the injected and the effective drug volume inside the IDDS reservoir after refills that did not lead to signs of overdose and to record at which volume discrepancy symptoms of overdose were noticed.After 221 refill procedures performed in 19 adult patients, drug volume inside the reservoir was assessed with a fill level sensor, and the volume discrepancy between injected and measured volume was recorded. Symptoms of overdose were monitored. For between group comparisons the Mann-Whitney U test was used, using a p-value of <0.05 to indicate statistical significance.The median volume discrepancy in the 20 mL IDDSs was 0.40 mL (IQR: 0.18-0.61; 10th p: 0.0; 90th p: 0.74) whereas in the 40 mL IDDSs the median volume discrepancy was 1.3 mL (IQR: 1.06-1.74; 10th p: 0.81; 90th p: 2.2). Symptoms of overdose were observed after 6 out of the 221 refill procedures. Volumes at which the symptoms of overdose arose were between 1.15 and 4.5 mL in 20 mL IDDSs and between 2.08 and 4.88 mL in 40 mL IDDSs.A volume discrepancy of >1 mL in 20 mL IDDSs and of >2 mL in 40 mL IDDSs after refill should be regarded as potentially consequential with regard to risk of overdose possibly caused by a pocket fill. In case of potentially consequential volume discrepancies, hospitalization and monitoring is recommended to preclude late overdose symptoms outside the hospital.

作者:Paolo, Maino;Roberto S G M, Perez;Eva, Koetsier

来源:Neuromodulation : journal of the International Neuromodulation Society 2017 年

相似文献
知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:38
作者:
Paolo, Maino;Roberto S G M, Perez;Eva, Koetsier
来源:
Neuromodulation : journal of the International Neuromodulation Society 2017 年
标签:
Chronic pain drug overdose intrathecal drug delivery intrathecal pump refill pocket fill spasticity
One complication associated with the refill procedure of intrathecal drug delivery systems (IDDSs) include a "pocket fill," which is the inadvertent injection of the drug into the subcutaneous space surrounding the pump. The purpose of our study was to assess the mean volume discrepancy between the injected and the effective drug volume inside the IDDS reservoir after refills that did not lead to signs of overdose and to record at which volume discrepancy symptoms of overdose were noticed.After 221 refill procedures performed in 19 adult patients, drug volume inside the reservoir was assessed with a fill level sensor, and the volume discrepancy between injected and measured volume was recorded. Symptoms of overdose were monitored. For between group comparisons the Mann-Whitney U test was used, using a p-value of <0.05 to indicate statistical significance.The median volume discrepancy in the 20 mL IDDSs was 0.40 mL (IQR: 0.18-0.61; 10th p: 0.0; 90th p: 0.74) whereas in the 40 mL IDDSs the median volume discrepancy was 1.3 mL (IQR: 1.06-1.74; 10th p: 0.81; 90th p: 2.2). Symptoms of overdose were observed after 6 out of the 221 refill procedures. Volumes at which the symptoms of overdose arose were between 1.15 and 4.5 mL in 20 mL IDDSs and between 2.08 and 4.88 mL in 40 mL IDDSs.A volume discrepancy of >1 mL in 20 mL IDDSs and of >2 mL in 40 mL IDDSs after refill should be regarded as potentially consequential with regard to risk of overdose possibly caused by a pocket fill. In case of potentially consequential volume discrepancies, hospitalization and monitoring is recommended to preclude late overdose symptoms outside the hospital.