To evaluate the expression of CD64 and CD163 on neutrophils and monocytes in SIRS with/without sepsis and to compare the diagnostic accuracy of CD64 and CD163 molecules expression determined as (1) mean fluorescence intensities (MFI) of CD64 and CD163; and (2) the ratio (index) of linearized MFI to the fluorescence signal of standardized beads.Fifty-six critically ill neonates and children with systemic inflammatory response syndrome (SIRS) and suspected sepsis, classified into two groups: SIRS with sepsis (n = 29) and SIRS without sepsis (n = 27).CD64 and CD163 MFI measured on neutrophils and monocytes were elevated in patients with SIRS with sepsis. Diagnostic accuracy of indexes was equal to diagnostic accuracy of MFI for CD64 on neutrophils (0.833 versus 0.854 for day 0 and 0.975 versus 0.983 for day 1) and monocytes (0.811 versus 0.865 for day 0 and 0.825 versus 0.858 for day 1), and CD163 on neutrophils (0.595 versus 0.655 for day 0 and 0.677 versus 0.750 for day 1), but not for CD163 on monocytes.CD64 MFI, CD163 MFI, CD64 indexes for neutrophils and monocytes, and CD163 index for neutrophils can all be used for discrimination of SIRS and sepsis in critically ill neonates and children. CD64 index for neutrophils, however, is superior to all other markers.

作者:Mojca, Groselj-Grenc;Alojz, Ihan;Metka, Derganc

来源:Mediators of inflammation 2008 年 2008卷

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:17
作者:
Mojca, Groselj-Grenc;Alojz, Ihan;Metka, Derganc
来源:
Mediators of inflammation 2008 年 2008卷
To evaluate the expression of CD64 and CD163 on neutrophils and monocytes in SIRS with/without sepsis and to compare the diagnostic accuracy of CD64 and CD163 molecules expression determined as (1) mean fluorescence intensities (MFI) of CD64 and CD163; and (2) the ratio (index) of linearized MFI to the fluorescence signal of standardized beads.Fifty-six critically ill neonates and children with systemic inflammatory response syndrome (SIRS) and suspected sepsis, classified into two groups: SIRS with sepsis (n = 29) and SIRS without sepsis (n = 27).CD64 and CD163 MFI measured on neutrophils and monocytes were elevated in patients with SIRS with sepsis. Diagnostic accuracy of indexes was equal to diagnostic accuracy of MFI for CD64 on neutrophils (0.833 versus 0.854 for day 0 and 0.975 versus 0.983 for day 1) and monocytes (0.811 versus 0.865 for day 0 and 0.825 versus 0.858 for day 1), and CD163 on neutrophils (0.595 versus 0.655 for day 0 and 0.677 versus 0.750 for day 1), but not for CD163 on monocytes.CD64 MFI, CD163 MFI, CD64 indexes for neutrophils and monocytes, and CD163 index for neutrophils can all be used for discrimination of SIRS and sepsis in critically ill neonates and children. CD64 index for neutrophils, however, is superior to all other markers.