您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览30

A new thermoresponsive polymer separation column was applied to simultaneous analysis of four cardiac glycosides (CGs) being widely used for the treatment of arrhythmias and heart failure in human blood and urine. This column is composed of an N-isopropylacrylamide polymer, the surface of which undergoes a reversible alteration from hydrophilic to hydrophobic by changing temperature. The chromatographic separation and retention times can be easily be controlled by adjusting the column temperature. As the column temperature was changed from 50 to 10 °C over 8 min, five CGs, including deslanoside, digoxin, methyldigoxin, digitoxin, and digitoxigenin (internal standard) were better resolved. Using these LC conditions, we analyzed four CGs in human whole blood and urine simultaneously by liquid chromatography-tandem mass spectrometry (LC-MS-MS). Validation data as functions of recovery rates, linearity, accuracy, and precision were carefully tested; all were generally satisfactory. The detection limits for the four CGs in both matrices were 0.2-0.3 ng/mL. The method was applied to analysis of methyldigoxin and its main metabolite digoxin in whole blood and urine samples obtained from a deceased person in actual autopsy case. To our knowledge, this is the first report describing an LC-MS-MS method using a thermoresponsive column for analysis of drug(s). The inclusion of the thermoresponsive column in an LC-MS-MS technique seems to extend the possibility for simultaneous analysis of compounds of different properties, such as hydrophobic precursors and their hydrophilic metabolites in biological samples within limited analysis times.

作者:Sanae, Kanno;Kanako, Watanabe;Itaru, Yamagishi;Seishiro, Hirano;Kayoko, Minakata;Kunio, Gonmori;Osamu, Suzuki

来源:Analytical and bioanalytical chemistry 2011 年 399卷 3期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:30
作者:
Sanae, Kanno;Kanako, Watanabe;Itaru, Yamagishi;Seishiro, Hirano;Kayoko, Minakata;Kunio, Gonmori;Osamu, Suzuki
来源:
Analytical and bioanalytical chemistry 2011 年 399卷 3期
A new thermoresponsive polymer separation column was applied to simultaneous analysis of four cardiac glycosides (CGs) being widely used for the treatment of arrhythmias and heart failure in human blood and urine. This column is composed of an N-isopropylacrylamide polymer, the surface of which undergoes a reversible alteration from hydrophilic to hydrophobic by changing temperature. The chromatographic separation and retention times can be easily be controlled by adjusting the column temperature. As the column temperature was changed from 50 to 10 °C over 8 min, five CGs, including deslanoside, digoxin, methyldigoxin, digitoxin, and digitoxigenin (internal standard) were better resolved. Using these LC conditions, we analyzed four CGs in human whole blood and urine simultaneously by liquid chromatography-tandem mass spectrometry (LC-MS-MS). Validation data as functions of recovery rates, linearity, accuracy, and precision were carefully tested; all were generally satisfactory. The detection limits for the four CGs in both matrices were 0.2-0.3 ng/mL. The method was applied to analysis of methyldigoxin and its main metabolite digoxin in whole blood and urine samples obtained from a deceased person in actual autopsy case. To our knowledge, this is the first report describing an LC-MS-MS method using a thermoresponsive column for analysis of drug(s). The inclusion of the thermoresponsive column in an LC-MS-MS technique seems to extend the possibility for simultaneous analysis of compounds of different properties, such as hydrophobic precursors and their hydrophilic metabolites in biological samples within limited analysis times.