您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览0

The purpose of this study was to measure power values generated in elite karate fighters during brief high intensity cycle ergometry when resistive forces were derived from total - body mass (TBM) or fat - free mass (FFM). Male international karate practitioners volunteered as participants (n = 11). Body density was calculated using hydrostatic weighing procedures with fat mass ascertained from body density values. Participants were required to pedal maximally on a cycle ergometer (Monark 864) against randomly assigned loads ranging from 70 g·kg(-1) - 95 g·kg(-1) (using a TBM or FFM protocol) for 8 seconds. The resistive force that produced the highest peak power output (PPO) for each protocol was considered optimal. Differences (p < 0.05) in peak power outputs were found between the TBM and FFM experimental condition (1164 ± 137 W vs. 1289 ± 145 W respectively). Differences were also recorded (p < 0.01) between pedal velocity and applied resistive forces (127 ± 8 rpm vs. 142 ± 7 rpm; 6.6 ± 1 kg vs. 5.5 ± 1 kg, respectively). No differences (p > 0.05) were observed between time to PPO, or heart rate when the TBM and FFM protocols were compared. The findings of this study suggest that when high intensity cycle ergometer resistive forces are derived from FFM, greater peak powers can be obtained consistently in karate athletes. Resistive forces that relate to the active muscle tissue utilised during this type of exercise may need to be explored in preference to protocols that include both lean and fat masses. The findings have implications for both exercise prescription and the evaluation of experimental results concerning karate athletes. Key PointsMethods for quantifying and measuring high intensity performance using high intensity cycle ergometry have received considerable attention in recent years.The assumption has been that the relationship between total - body mass (TBM) and fat - free mass (FFM) is the same.However, variations in body composition between participants may under or over estimate cradle resistive forces used in high intensity cycle ergometry power assessment.This may lead to spurious calculations of power.The findings of this study demonstrate that the total capacity, power and relative contribution of the energy systems involved during experimental high intensity cycle ergometer exercise need re - evaluating.

作者:Julien Steven, Baker;Bruce, Davies

来源:Journal of sports science & medicine 2006 年 5卷 CSSI期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:0
作者:
Julien Steven, Baker;Bruce, Davies
来源:
Journal of sports science & medicine 2006 年 5卷 CSSI期
标签:
Anaerobic performance body composition
The purpose of this study was to measure power values generated in elite karate fighters during brief high intensity cycle ergometry when resistive forces were derived from total - body mass (TBM) or fat - free mass (FFM). Male international karate practitioners volunteered as participants (n = 11). Body density was calculated using hydrostatic weighing procedures with fat mass ascertained from body density values. Participants were required to pedal maximally on a cycle ergometer (Monark 864) against randomly assigned loads ranging from 70 g·kg(-1) - 95 g·kg(-1) (using a TBM or FFM protocol) for 8 seconds. The resistive force that produced the highest peak power output (PPO) for each protocol was considered optimal. Differences (p < 0.05) in peak power outputs were found between the TBM and FFM experimental condition (1164 ± 137 W vs. 1289 ± 145 W respectively). Differences were also recorded (p < 0.01) between pedal velocity and applied resistive forces (127 ± 8 rpm vs. 142 ± 7 rpm; 6.6 ± 1 kg vs. 5.5 ± 1 kg, respectively). No differences (p > 0.05) were observed between time to PPO, or heart rate when the TBM and FFM protocols were compared. The findings of this study suggest that when high intensity cycle ergometer resistive forces are derived from FFM, greater peak powers can be obtained consistently in karate athletes. Resistive forces that relate to the active muscle tissue utilised during this type of exercise may need to be explored in preference to protocols that include both lean and fat masses. The findings have implications for both exercise prescription and the evaluation of experimental results concerning karate athletes. Key PointsMethods for quantifying and measuring high intensity performance using high intensity cycle ergometry have received considerable attention in recent years.The assumption has been that the relationship between total - body mass (TBM) and fat - free mass (FFM) is the same.However, variations in body composition between participants may under or over estimate cradle resistive forces used in high intensity cycle ergometry power assessment.This may lead to spurious calculations of power.The findings of this study demonstrate that the total capacity, power and relative contribution of the energy systems involved during experimental high intensity cycle ergometer exercise need re - evaluating.