您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览49

Assessing vitamin E status in humans is critical for nutritional evaluation and verification of clinical and biological compliance of supplemented subjects. An accurate analytical method for measuring the two main vitamin E isoforms, i.e. α- and γ-tocopherol (α- and γ-TOH) in small volumes of plasma can facilitate the application of this analysis to clinical trials and in situations where a limited amount of sample is available.We have developed a micro method, which uses only 5 μL plasma, based on isotope dilution, trimethylsilation and GC-MS. The method was validated according to the guidelines of the International Conference on Harmonization of analytical procedures. The method was also applied to 5 μL of whole blood for the potential use in conditions were the availability of specimens is limited.Accurate quantitation of α-TOH and γ-TOH was achieved at levels ≥ 0.417 μM and ≥ 0.007 μM, respectively. Within-day coefficient of variation was 1.31

作者:C, Zerbinati;F, Galli;R, Regolanti;G, Poli;L, Iuliano

来源:Clinica chimica acta; international journal of clinical chemistry 2015 年 446卷

相似文献
知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:49
作者:
C, Zerbinati;F, Galli;R, Regolanti;G, Poli;L, Iuliano
来源:
Clinica chimica acta; international journal of clinical chemistry 2015 年 446卷
标签:
Antioxidants Lipid peroxidation Method Oxidative stress Vitamin E
Assessing vitamin E status in humans is critical for nutritional evaluation and verification of clinical and biological compliance of supplemented subjects. An accurate analytical method for measuring the two main vitamin E isoforms, i.e. α- and γ-tocopherol (α- and γ-TOH) in small volumes of plasma can facilitate the application of this analysis to clinical trials and in situations where a limited amount of sample is available.We have developed a micro method, which uses only 5 μL plasma, based on isotope dilution, trimethylsilation and GC-MS. The method was validated according to the guidelines of the International Conference on Harmonization of analytical procedures. The method was also applied to 5 μL of whole blood for the potential use in conditions were the availability of specimens is limited.Accurate quantitation of α-TOH and γ-TOH was achieved at levels ≥ 0.417 μM and ≥ 0.007 μM, respectively. Within-day coefficient of variation was 1.31