您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览40

We aimed to evaluate the relationship between insulin pharmacodynamics and glycaemic outcomes during closed-loop insulin delivery and sensor-augmented pump therapy. We retrospectively analysed data from a multicentre randomized control trial involving 32 adults with type 1 diabetes receiving day-and-night closed-loop insulin delivery and sensor-augmented pump therapy over 12 weeks. We estimated time-to-peak insulin action (t max,IA ) and insulin sensitivity ( S I ) during both interventions, and correlated these with demographic factors and glycaemic outcomes. During both interventions, t max,IA was positively correlated with pre- and post-intervention HbA1c (r = 0.50-0.52, P  < .01) and mean glucose (r = 0.45-0.62, P  < .05), and inversely correlated with time sensor glucose, which was in target range 3.9 to 10 mmol/L (r = -0.64 to -0.47, P  < .05). Increased body mass index was associated with higher t max,I and lower S I (both P  < .05). During closed-loop insulin delivery, t max,IA was positively correlated with glucose variability ( P  < .05). Faster insulin action is associated with improved glycaemic control during closed-loop insulin delivery and sensor-augmented pump therapy.

作者:Yue, Ruan;Hood, Thabit;Lalantha, Leelarathna;Sara, Hartnell;Malgorzata E, Wilinska;Martin, Tauschmann;Sibylle, Dellweg;Carsten, Benesch;Julia K, Mader;Manuel, Holzer;Harald, Kojzar;Mark L, Evans;Thomas R, Pieber;Sabine, Arnolds;Roman, Hovorka

来源:Diabetes, obesity & metabolism 2017 年

相似文献
知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:40
作者:
Yue, Ruan;Hood, Thabit;Lalantha, Leelarathna;Sara, Hartnell;Malgorzata E, Wilinska;Martin, Tauschmann;Sibylle, Dellweg;Carsten, Benesch;Julia K, Mader;Manuel, Holzer;Harald, Kojzar;Mark L, Evans;Thomas R, Pieber;Sabine, Arnolds;Roman, Hovorka
来源:
Diabetes, obesity & metabolism 2017 年
标签:
CSII glycaemic control insulin delivery insulin pump therapy pharmacodynamics type 1 diabetes
We aimed to evaluate the relationship between insulin pharmacodynamics and glycaemic outcomes during closed-loop insulin delivery and sensor-augmented pump therapy. We retrospectively analysed data from a multicentre randomized control trial involving 32 adults with type 1 diabetes receiving day-and-night closed-loop insulin delivery and sensor-augmented pump therapy over 12 weeks. We estimated time-to-peak insulin action (t max,IA ) and insulin sensitivity ( S I ) during both interventions, and correlated these with demographic factors and glycaemic outcomes. During both interventions, t max,IA was positively correlated with pre- and post-intervention HbA1c (r = 0.50-0.52, P  < .01) and mean glucose (r = 0.45-0.62, P  < .05), and inversely correlated with time sensor glucose, which was in target range 3.9 to 10 mmol/L (r = -0.64 to -0.47, P  < .05). Increased body mass index was associated with higher t max,I and lower S I (both P  < .05). During closed-loop insulin delivery, t max,IA was positively correlated with glucose variability ( P  < .05). Faster insulin action is associated with improved glycaemic control during closed-loop insulin delivery and sensor-augmented pump therapy.