您的账号已在其他设备登录,您当前账号已强迫下线,
如非您本人操作,建议您在会员中心进行密码修改

确定
收藏 | 浏览12 | 下载0

The operating corneoloscope and Terry operative keratometer were used respectively in 29 and 34 eyes during the intraocular lens implanta-tion to measure the corneal astigmatism qualitatively or quantitatively,so that the tension of incision closure could be adjusted.The surgically induced astig-matism in qualitative group two weeks after the operation was 3.5±1.70 D and that in quantitative group was 2.56±1.60 D.There were 55.17% and 38.24 % of the eyes with over 2.00 D corneal astigmatism in qualitative and quan-titative group two months after the surgery.The astigmatism of both groups at the early stage after the operation was significantly lower than that of the con-trol group (p<0.05).Argon laser,Nd:YAG laser or razor-blade were used to cut 1 to 3 limbal sutures in 64 eyes with over with-the-rule astigmatism 2.25 D at the early stage (2 months) after the operation.One hour after suture cut-ting,the with-the-rule corneal astigmatism reduced significantly with an aver-age of 2.61 D.The astigmatism c

作者:Yizi Liu;Shaozhen Li;Jiaqi Chen

来源:眼科学报 1994 年 10卷 1期

知识库介绍

临床诊疗知识库该平台旨在解决临床医护人员在学习、工作中对医学信息的需求,方便快速、便捷的获取实用的医学信息,辅助临床决策参考。该库包含疾病、药品、检查、指南规范、病例文献及循证文献等多种丰富权威的临床资源。

详细介绍
热门关注
免责声明:本知识库提供的有关内容等信息仅供学习参考,不代替医生的诊断和医嘱。

收藏
| 浏览:12 | 下载:0
作者:
Yizi Liu;Shaozhen Li;Jiaqi Chen
来源:
眼科学报 1994 年 10卷 1期
标签:
intraoular lens implantation surgically induced corneal astigma-tism laser suture cutting arcuate keratotomy
The operating corneoloscope and Terry operative keratometer were used respectively in 29 and 34 eyes during the intraocular lens implanta-tion to measure the corneal astigmatism qualitatively or quantitatively,so that the tension of incision closure could be adjusted.The surgically induced astig-matism in qualitative group two weeks after the operation was 3.5±1.70 D and that in quantitative group was 2.56±1.60 D.There were 55.17% and 38.24 % of the eyes with over 2.00 D corneal astigmatism in qualitative and quan-titative group two months after the surgery.The astigmatism of both groups at the early stage after the operation was significantly lower than that of the con-trol group (p<0.05).Argon laser,Nd:YAG laser or razor-blade were used to cut 1 to 3 limbal sutures in 64 eyes with over with-the-rule astigmatism 2.25 D at the early stage (2 months) after the operation.One hour after suture cut-ting,the with-the-rule corneal astigmatism reduced significantly with an aver-age of 2.61 D.The astigmatism c